Extension Terminal alone with the
internal magnet switch being bypassed
or to use both of them together.
If you choose to have both of the internal
magnetic Switch and Extension Terminal
work together, then.
z When the protected door is being opened or
the enteral device is triggered, the Open
Contact is activated and will transmit a
violation signal
However The Open Contact will transmit a “Door
Closed” or “Restored Signal” only affer the protected
door
and the violated device being restored.
Appendix
I.ChangingtheBatteries
When the Control Panel is in Low Battery condition, it
will display a low battery fault message when any key
is pressed, with a two-tone beep to remind you the
battery needs replacement.
PROBLEM? 17
Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to
help you make a perfect installation.
To Change Battery:
z Disable tamper protection by putting the Control
Panel into Programming Mode.
<
<
N
N
O
O
T
T
E
E
>
>
) The Programming Mode will
automatically quit after 10 minutes if no
keys are pressed.
z Loosen front screw with a coin and hinge front
away from base.
z Remove battery compartment screws and lid.
z Remove the old batteries.
z Insert new batteries with alkaline replacements.
Before inserting the 4
th
battery:
z Press and hold down the “RESET BUTTON
(that can be found as pointed below in the picture)
and put in the 4
th
battery at the same time. :
z Release the “RESET BUTTON
z Replace battery compartment lid and front.
<
<
N
N
O
O
T
T
E
E
>
>
) Always use alkaline batteries as
replacements to ensure long service life.
II.ResetProcedure
1. Control Panel User and Master
Codes Reset
The Control Panel can reset all user and master codes
without resetting programmed parameters by the
following sequence:
Step 1. Disable tamper protection by putting the
Control Panel into Programming Mode.
<
<
N
N
O
O
T
T
E
E
>
>
) The Programming Mode will
automatically quit after 10 minutes if no
keys are pressed.
Step 2. Press the “S” key and then the “RESET
BUTTON” simultaneously.